Water treatment for heating systems and heat pumps
Scale, sludge and corrosion reduce the efficiency of boilers and heat pumps and shorten their life. We check the system, define the treatments required by the applicable standards and make sure they are carried out.
A clean, protected circuit
Treatment concerns both the fill water and the water circulating in the system.
1. Analysis
Hardness, pH, conductivity and iron of the system water.
2. Flushing
Cleaning existing circuits of sludge and deposits.
3. Filtration
Safety filter and magnetic dirt separator on the return.
4. Softening
Low-hardness fill and top-up water.
5. Conditioning
Corrosion and scale inhibitors, antifreeze where needed.
6. Checks
Periodic parameter checks and records.
Why treat heating water
A few millimetres of scale on heat exchangers are enough to raise consumption. Iron oxide sludge (magnetite) clogs valves, pumps and plate heat exchangers, and corrosion causes leaks that are hard to find. Condensing boilers and heat pumps, with compact heat exchangers, are the most sensitive.
What the standards require
Several countries set requirements for heating water treatment. In Italy, for example, standard UNI 8065 defines water characteristics and treatments for heating and domestic hot water systems, and is referenced by energy efficiency rules for new systems and boiler replacements; in general it requires safety filtration, chemical conditioning and, depending on hardness and system output, softening. Requirements are checked case by case for the country of installation.
Existing systems
When replacing a boiler or installing a heat pump on an old system, flushing the circuits before connecting the new generator avoids passing on years of sludge and deposits.
Hotels, residential complexes and large villas
In central systems, water treatment protects significant investments. Domestic hot water must also be managed with Legionella risk in mind.
What we manage for you
System and water check, definition of treatments, selection of the company that carries them out, supervision of works and of the documentation for the system logbook.
Heating systems: common questions
Does it apply to heat pumps too?
Yes. Heat pumps have compact heat exchangers that are sensitive to sludge and scale: a clean, protected circuit preserves efficiency and service life.
I already have a softener for the house: is that enough?
No. The softener treats domestic water; the heating circuit needs filtration, conditioning and suitable fill water.
Do magnetic dirt separators work?
Yes: they capture the iron oxide particles circulating in the system. They are different from magnetic descalers, which we do not recommend.
How often should system water be checked?
At least at each periodic boiler or heat pump service, and whenever a lot of water is added to the circuit.
Other treatments
Protect boilers and heat pumps
We help you set up the right treatment and have it carried out.